Details
114EZNM Andrew Type N Male EZfit® for 1-1/4 in AVA6-50 Heliax Cable
MFR: Andrew / Commscope
General Specifications
- Interface: N Male
- Body Style: Straight
- Brand: EZfit®
- Mounting Angle: Straight
Electrical Specifications
- Connector Impedance: 50 ohm
- Operating Frequency Band: 0 – 3300 MHz
- Cable Impedance: 50 ohm
- 3rd Order IMD, typical: -116 dBm @ 1800 MHz
- 3rd Order IMD Test Method: Two +43 dBm carriers
- RF Operating Voltage, maximum (vrms): 707.00 V
- dc Test Voltage: 2000 V
- Outer Contact Resistance, maximum: 0.30 mOhm
- Inner Contact Resistance, maximum:2.00 mOhm
- Insulation Resistance, minimum: 5000 MOhm
- Average Power: 0.6 kW @ 900 MHz
- Peak Power, maximum: 10.00 kW
- Insertion Loss, typical: 0.05 dB
- Shielding Effectiveness: -130 dB
Mechanical Specifications
- Outer Contact Attachment Method: Clamp
- Inner Contact Attachment Method: Captivated
- Outer Contact Plating: Trimetal
- Inner Contact Plating: Silver
- Attachment Durability: 25 cycles
- Interface Durability: 500 cycles
- Interface Durability Method: IEC 61169-4:9.5
- Connector Retention Tensile Force: 1334 N | 300 lbf
- Connector Retention Torque: 8.13 N-m | 72.00 in lb
- Insertion Force: 66.72 N | 15.00 lbf
- Insertion Force Method: IEC 61169-1:15.2.4
- Pressurizable: No
- Coupling Nut Proof Torque: 24.86 N-m | 220.00 in lb
- Coupling Nut Retention Force: 1000.85 N | 225.00 lbf
- Coupling Nut Retention Force Method: MIL-C-39012C-3.25, 4.6.22
Dimensions
- Nominal Size: 1-1/4 in
- Diameter: 49.00 mm | 1.93 in
- Length: 72.00 mm | 2.83 in
- Weight: 302.00 g | 0.67 lb
Environmental Specifications
- Operating Temperature: -40 °C to +85 °C (-40 °F to +185 °F)
- Storage Temperature: -55 °C to +85 °C (-67 °F to +185 °F)
- Immersion Depth: 1 m
- Immersion Test Mating: Mated
- Immersion Test Method: IEC 60529:2001, IP68
- Water Jetting Test Mating: Mated
- Water Jetting Test Method: IEC 60529:2001, IP66
- Moisture Resistance Test Method: MIL-STD-202F, Method 106F
- Mechanical Shock Test Method: MIL-STD-202F, Method 213B, Test Condition C
- Vibration Test Method: IEC 60068-2-6
- Corrosion Test Method: MIL-STD-1344A, Method 1001.1, Test Condition A
Standard Conditions
- Attenuation, Ambient Temperature: 20 °C | 68 °F
- Average Power, Ambient Temperature: 40 °C | 104 °F
Return Loss/VSWR
Frequency Band VSWR Return Loss (dB)
50–1000 MHz 1.03 38.00
1000–1900 MHz 1.03 37.00
1900–2200 MHz 1.04 35.00
2200–2700 MHz 1.05 33.00
2700–3300 MHz 1.07 30.00
Additional Information
Featured Product | No |
---|---|
Made in the USA | No |
GTIN | No |
ISBN | No |
NATO Stock Number | No |
Manufacturer Part Number | No |
Manufacturer | Andrew / Commscope |
Condition | New |
NOS | No |
Call For Price | No |
Manufacturer Name | ANDREW / COMMSCOPE |