Details
L6TDF-PS Andrew 7-16 DIN Female Positive Stop™ for 1-1/4" LDF6-50 Cable
New Old Stock * No longer available for export
MFR: Andrew
General Specifications
- Interface 7-16 DIN Female
- Body Style Straight
- Brand HELIAX® | Positive Stop™
- Mounting Angle Straight
Electrical Specifications
- Connector Impedance 50 ohm
- Operating Frequency Band 0 – 3300 MHz
- Cable Impedance 50 ohm
- 3rd Order IMD, typical -120 dBm @ 910 MHz
- 3rd Order IMD Test Method Two +43 dBm carriers
- RF Operating Voltage, maximum (vrms) 1415.00 V
- dc Test Voltage 4000 V
- Outer Contact Resistance, maximum 1.50 mOhm
- Inner Contact Resistance, maximum 0.80 mOhm
- Insulation Resistance, minimum 5000 MOhm
- Average Power 3.0 kW @ 900 MHz
- Peak Power, maximum 40.00 kW
- Insertion Loss, typical 0.05 dB
- Shielding Effectiveness -130 dB
Mechanical Specifications
- Outer Contact Attachment Method Ring-flare
- Inner Contact Attachment Method Captivated
- Outer Contact Plating Trimetal
- Inner Contact Plating Silver
- Attachment Durability 25 cycles
- Interface Durability 50 cycles
- Interface Durability Method IEC 61169-16:9.5
- Connector Retention Tensile Force 1779 N | 400 lbf
- Connector Retention Torque 10.85 N-m | 96.00 in lb
- Insertion Force 200.17 N | 45.00 lbf
- Insertion Force Method IEC 61169-1:15.2.4
- Pressurizable No
Dimensions
- Nominal Size 1-1/4 in
- Diameter 51.21 mm | 2.02 in
- Length 89.00 mm | 3.50 in
- Weight 650.00 g | 1.43 lb
Environmental Specifications
- Operating Temperature -55 °C to +85 °C (-67 °F to +185 °F)
- Storage Temperature -55 °C to +85 °C (-67 °F to +185 °F)
- Immersion Depth 1 m
- Immersion Test Mating Unmated
- Immersion Test Method IEC 60529:2001, IP68
- Water Jetting Test Mating Unmated
- Water Jetting Test Method IEC 60529:2001, IP66
- Moisture Resistance Test Method MIL-STD-202F, Method 106F
- Mechanical Shock Test Method MIL-STD-202F, Method 213B, Test Condition C
- Thermal Shock Test Method MIL-STD-202F, Method 107G, Test Condition A-1, Low Temperature -55 °C
- Vibration Test Method MIL-STD-202F, Method 204D, Test Condition B
- Corrosion Test Method MIL-STD-1344A, Method 1001.1, Test Condition A
Standard Conditions
- Attenuation, Ambient Temperature 20 °C | 68 °F
- Average Power, Ambient Temperature 40 °C | 104 °F
You may also be interested in the following product(s)
Additional Information
Featured Product | No |
---|---|
Made in the USA | No |
GTIN | No |
ISBN | No |
NATO Stock Number | No |
Manufacturer Part Number | No |
Manufacturer | Andrew |
Condition | New |
NOS | No |
Call For Price | No |
Manufacturer Name | ANDREW |