Details
AL5E78-PS 7/8 in EIA Positive Stop™ for 7/8 in AVA5-50 and AL5-50 cable
Connector comes with center connector and hardware.
NOTE: FOR AVA5-50 CABLE EXCLUSIVELY. WILL NOT WORK ON AVA5-50FX.
|
General Specifications |
Interface |
7/8 in EIA Flange |
Body Style |
Straight |
Brand |
HELIAX® | Positive Stop™ |
Mounting Angle |
Straight |
|
Electrical Specifications |
Connector Impedance |
50 ohm |
Operating Frequency Band |
0 – 5000 MHz |
Cable Impedance |
50 ohm |
3rd Order IMD, typical |
-116 dBm @ 910 MHz |
3rd Order IMD Test Method |
Two +43 dBm carriers |
RF Operating Voltage, maximum (vrms) |
2120.00 V |
dc Test Voltage |
6000 V |
Outer Contact Resistance, maximum |
1.50 mOhm |
Inner Contact Resistance, maximum |
1.50 mOhm |
Insulation Resistance, minimum |
5000 MOhm |
Average Power |
2.3 kW @ 900 MHz |
Peak Power, maximum |
90.00 kW |
Insertion Loss, typical  |
0.05 dB |
Shielding Effectiveness |
-130 dB |
|
Outline Drawing |
|
Click on image below to enlarge.
 |
|
|
|
|
Mechanical Specifications |
Outer Contact Attachment Method |
Ring-flare |
Inner Contact Attachment Method |
Captivated |
Outer Contact Plating |
Trimetal |
Inner Contact Plating |
Silver |
Attachment Durability |
25 cycles |
Interface Durability |
50 cycles |
Connector Retention Tensile Force |
1335 N | 300 lbf |
Connector Retention Torque |
8.10 N-m | 71.69 in lb |
Insertion Force |
66.72 N | 15.00 lbf |
Insertion Force Method |
IEC 61169-1:15.2.4 |
Pressurizable |
No |
Coupling Nut Proof Torque |
24.86 N-m | 220.00 in lb |
|
Dimensions |
Nominal Size |
7/8 in |
Diameter |
57.23 mm | 2.25 in |
Length |
88.74 mm | 3.49 in |
Weight |
340.21 g | 0.75 lb |
|
Environmental Specifications |
Operating Temperature |
-55 °C to +85 °C (-67 °F to +185 °F) |
Storage Temperature |
-55 °C to +85 °C (-67 °F to +185 °F) |
Immersion Depth  |
1 m |
Immersion Test Mating |
Unmated |
Immersion Test Method |
IEC 60529:2001, IP68 |
Water Jetting Test Mating |
Unmated |
Water Jetting Test Method |
IEC 60529:2001, IP66 |
Moisture Resistance Test Method |
MIL-STD-202F, Method 106F |
Mechanical Shock Test Method |
MIL-STD-202, Method 213, Test Condition I |
Thermal Shock Test Method |
MIL-STD-202F, Method 107G, Test Condition A-1, Low Temperature -55 °C |
Vibration Test Method |
MIL-STD-202F, Method 204D, Test Condition B |
Corrosion Test Method |
MIL-STD-1344A, Method 1001.1, Test Condition A |
|
Standard Conditions |
Attenuation, Ambient Temperature |
20 °C | 68 °F |
Average Power, Ambient Temperature |
40 °C | 104 °F |
Return Loss/VSWR
Frequency Band |
VSWR |
Return Loss (dB) |
50–1000 MHz |
1.04 |
35.00 |
1700–2200 MHz |
1.04 |
35.00 |
2400–2700 MHz |
1.07 |
30.00 |
3400–3600 MHz |
1.12 |
25.00
|
MFR: Andrew/Commscope