NOTE:  Due to the cable shortage in the US, we have very limited quantity available.  We only have 50 foot pre-cut lengths in stock. The next scheduled delivery is the middle of September.  We suggest EC4-50 Eupen cable as a direct replacement for your urgent requirements.  Please let us know if we can help further.


Jacket Material: PE


Outer Conductor Material: Corrugated copper
Dielectric Material: Foam PE
Flexibility; Standard
Inner Conductor Material: Copperclad Aluminum Wire
Jacket Color: Black
Cable Impedance 50 ohm ±1 ohm


All HELIAX coaxial cables are jacketed for direct burial or
for corrosive environmental conditions. Standard jacketing
material is weather-resistant polyethylene suitable for use
in extreme climates.


NSN: 6145-01-534-6922
MFR: CommScope® / Andrew
SKU: LDF4-50A
Sold by the Foot.

Made in the USA

Be the first to review this product


Details

LDF4-50A CommScope® / Andrew HELIAX® 1/2" Low Density Foam Coaxial Cable

Construction Materials
Jacket Material: PE
Outer Conductor Material: Corrugated copper
Dielectric Material: Foam PE
Flexibility; Standard
Inner Conductor Material: Copperclad Aluminum Wire
Jacket Color: Black

Dimensions
Nominal Size: 1/2 in
Cable Weight: 0.15 lb/ft | 0.22 kg/m
Diameter Over Dielectric: 12.954 mm | 0.510 in
Diameter Over Jacket:15.875 mm | 0.625 in
Inner Conductor OD: 4.8260 mm | 0.1900 in
Outer Conductor OD: 13.970 mm | 0.550 in

Electrical Specifications
Cable Impedance: 50 ohm ±1 ohm
Capacitance: 23.1 pF/ft | 75.8 pF/m
dc Resistance, Inner Conductor 0.450 ohms/kft | 1.480 ohms/km
dc Resistance, Outer Conductor 0.580 ohms/kft | 1.903 ohms/km
dc Test Voltage: 4000 V
Inductance: 0.190 μH/m | 0.058 μH/ft
Insulation Resistance: 100000 MOhm
Jacket Spark Test Voltage (rms): 8000 V
Operating Frequency Band: 1 – 8800 MHz
Peak Power: 40.0 kW
Pulse Reflection: 0.5%
Velocity: 88%

Environmental Specifications
Installation Temperature: 40
°C to +60 °C (40
°F to +140 °F)

All HELIAX® coaxial cables are jacketed for direct burial or for corrosive environmental conditions.
Standard jacketing material is weather-resistant polyethylene suitable for use in extrem

Made in the USA

Additional Information

Featured Product No
Made in the USA Yes
Manufacturer No
NOS No
Call For Price No
Manufacturer Name Andrew

Product Attachments

Andrew LDF4-50A Heliax Cable This is the product specification sheet for Andrew Heliax Cable LDF4-50A pdf 963.43 KB Download

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.